Powerful analysis software, on us
With the free PWRVIEW software suite and Tektronix power Analyzers, you’ll have a powerful analysis tool that eliminates the need to write and maintain your own software. That makes long and laborious efficiency testing, power consumption testing, AC or DC power analysis, 3-phase power analysis, or harmonics analysis easier and more efficient.
Comply with confidence
The PA3000 with PWRVIEW software and PDF reporting simplifies pre- and full-compliance testing for various regulatory standards. Be confident that you’ll pass third party compliance tests at release, reducing repeat tests and design revisions that would cost you time and money.
Highlights
- IEC62301 standby power compliance down to 10 mW
- LEVEL VI (EPS) efficiency testing
- Energy Star, CEC and CQC testing
- MIL-1399 Current Harmonics testing
Future-proof accuracy and resolution
Because the PA3000 easily exceeds most regulatory standard requirements for power analyzer accuracy and resolution specifications, your investment is essentially future proofed for years to come.
Highlights
- High basic accuracy: 0.04% on volts and amps
- Wide power measuring range, from 10 mWs to high MWs
- 16 bit A/D for high resolution
Harmonic bandwidth and sampling rate you need
The PA3000 does not restrict the signals to low bandwidth. Instead, it captures the complete picture to show the effects of high frequency harmonics on the voltage and current measurements, setting it apart from other power meters in its class. Harmonic content can be analyzed for fundamental frequencies up to 100 kHz, and bandwidth filters are available where needed.
Highlights
- Wide 1 MHz bandwidth for high frequency harmonics
- High 1 Ms/S sampling rate for a detailed picture
- Test harmonics to 100th order
Model | Number of Channels | Basic Accuracy (V & I) | Max Voltage Input | Max Current Input | Measurement Bandwidth | List Price |
---|---|---|---|---|---|---|
PA3000 | 1-4 | 0.04% reading + 0.04% range | 600 Vrms CAT II (2000Vpk) | 30 Arms | DC to 1 MHz | Configure & Quote |
Tektronix PA3000 | Tektronix PA1000 | |
---|---|---|
Description | Multi channel Power Analyzer optimized for single and three phase efficiency testing, power and harmonic analysis on AC-DC power supply, LED lighting, UPS Systems, Inverters, power converters and PWM motor drives. | Single channel Power Analyzer optimized for energy consumption, input AC power and harmonic analysis on home and office appliances, power supplies, lighting products and consumer electronics. |
Applications | 1-3Ph – Efficiency Testing, Three phase power analysis, Harmonic analysis, Energy consumption testing, Standby power testing, Torque, Speed, Humidity and Temp monitoring. | 1ph – Energy consumption testing, Input power analysis, Standby power testing, Current harmonics testing. |
Free PWRVIEW Software | Remote operation, Logging, Application wizards, Effciency Testing, Result grid, Harmonics chart, waveforms, Trend, Pass/Fail limits, Custom formulas, IEC62301 ED 2 test, MIL-1399 test | Remote operation, Logging, Application wizards, Result grid, Harmonics chart, waveforms, Trend, Pass/Fail limits, Custom formual, IEC62301 ED 2 test, IEC61000-3-2 test |
Channels | 1, 2, 3 or 4 (Optional) | 1 |
Voltage Ratings | 600Vrms Cat II | 600Vrms Cat II |
Current Ratings | 30Arms and 1Arms Internal Shunts | 20Arms and 1Arms Internal Shunts |
External Current Inputs | 20Vpk (2mm Banana Plug) | 1.25Vpk (2mm Banana Plug) |
AC Voltage and Current Accuracy (45Hz – 850Hz) | 0.04% rdg + 0.04% range | 0.04%rdg+0.04% range |
DC Voltage and Current Accuracy | 0.05% rdg + 0.1% range | 0.1% reading + 0.1% range |
Power Accuracy (45Hz – 850Hz) | ± (Vrmsacc × Arms) ± (Armsacc × Vrms) | ± 0.075% of Reading ± 0.075% of Range |
Bandwidth | 1MHz | 1MHz |
Sampling Rate | 1 Million Samples per Second | 1 Million Samples per Second |
Voltage Ranges (Peak) | 5 V, 10 V, 20 V, 50 V, 100 V, 200 V, 500 V, 1000 V, 2000 V | 10 V, 20 V, 50 V, 100 V, 200 V, 500 V, 1000 V |
Current Ranges (Peak) | 30 A shunt: 500mA, 1 A, 2 A, 5 A, 10 A, 20 A, 50 A, 100 A, 200A 1A shunt: 12.5 mA, 25 mA, 50 mA, 125 mA, 250 mA, 500 mA, 1.25 A, 2.5 A, 5 A | 20A Shunt: 100mA, 200 mA, 500m A, 1 A, 2 A, 5 A, 10 A, 20 A, 50 A, 100 A 1A Shunt: 2mA, 4mA, 10mA, 20mA, 40mA, 100mA, 200mA, 400mA, 1A, 2A |
Ext Current Input Ranges (peak) | 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V, 5 V, 10 V, 20 V | 12.5 mV, 25 mV, 62.5 mV, 125 mV, 250 mV, 625 mV, 1.25 V |
Default Application Modes | PWM Motor, Integrator, Standby Power, Ballast, Normal | Integrator, Standby Power, Inrush, Ballast, Normal |
Available Measurements | 52 | 29 |
Harmonics | up to 100th order | upto 50th order |
Wiring Configurations | 1ph-2w, 1ph-3w, 3ph-3w, 3ph-4w, 3ph-3w(3V3A) | 1ph-2w |
Update Rate | 50mS | 500mS |
Display Screen | 5.75″ Graphical Color Display | 3.5″ Graphical Color Display |
Auxiliary Inputs (Torque, Speed, Temperature, etc) | 4 Analog inputs: +10 V to -10 V 2 Counter inputs: +10 V to -10V ; 1Mhz 4 Digital outputs: +5 V TTL with 10 kΩ output impedance | N/A |
Communication Ports | USB Host, USB, Ethernet, RS232, GPIB (optional) | USB Host, USB, Ethernet, GPIB |
Trasducer Power Supply | ± 15 V, Max current 250 mA per channel | N/A |
Power Input | 100 V to 240 V AC, 50 Hz or 60 Hz, 120 VA maximum | 100 V to 240 V AC, 50 Hz or 60 Hz, 25 VA maximum |
Warranty | 3 Years | 3 Years |
EMC | Conforms to European Union EMC Directive | Conforms to European Union EMC Directive |
Safety | Conforms to European Union Low Voltage Directive | Conforms to European Union Low Voltage Directive |
Dimension (Without Handle) | 13.2 cm high × 42 cm wide × 33.5 cm deep (5.2” × 16.5” × 13.2”) | 10.2cm high x 22.3cm wide x 28.5cm deep ( 4.0″ x 8.7″ x 11.2″) |
Weight | 9.5 kg (20.9 lb.) – 4 Ch with GPIB | 3.2 kg (7.0 lb.) |
AC-DC power supply and LED driver testing
With high accuracy and high resolution, the PA3000 offers an ideal mix of features and specifications to accurately test power and efficiency on your AC/DC power supply and LED driver designs.
Highlights
- High basic accuracy: 0.04% on volts and amps
- IEC62301 standby power testing down to 10 mW
- Custom limits setup for pass/fail testing
- 1 Ms/S sampling and peak detect for inrush testing
Home appliance and consumer electronics testing
The PA3000 is equipped with a default power consumption testing mode, PWRVIEW’s advanced auto-up ranging, and long term logging features. This robust combination makes it the best energy meter solution for testing power and energy consumption on modern home appliances, consumer electronics, battery chargers, and hand tools.
Highlights
- Integrator mode for easy energy consumption testing
- Auto-up ranging for accurate readings on variable loads
- IEC62301 power consumption testing with pdf report
- Energy Star, CEC and CQC testing
Solar inverters and UPS systems
Four channels, wide bandwidth, a wide current range of 90 µA to 30 A, and available external CTs make the PA3000 ideal for testing all stages of high power solar PV inverters and UPS systems, including DC and AC power stages.
Highlights
- Wide 1 MHz bandwidth for high frequency harmonics
- High 1 Ms/S sampling rate for a detailed picture
- Test harmonics to 100th order
Wired and wireless automotive battery chargers
Test high frequency wireless power transfer and harmonics, in addition to low frequency AC and DC signals, with wide harmonic bandwidth and wide power range.
Highlights
- 4 available channels for full system efficiency testing
- 1 MHz bandwidth for high frequency harmonic analysis
- 30 A current shunt with available high current CTs
- Standard 15 V supply for external CTs
3-phase power analysis and PWM motor drives
Analyze 3-phase PWM motor drive output power and system efficiency with a dedicated PWM mode to decode complex signals such as fundamental carrier frequency from high frequency modulated voltage.
Highlights
- Dedicated PWM mode for PWM voltage filtering
- Available 3ph-3w and 3ph-4w for efficiency test
- Torque and speed inputs for mechanical efficiency testing
- 30A current shunt with available high current CTs
Data Sheet | Accessory | Description | Pricing | |
---|---|---|---|---|
Datasheet | BB1000-EU | Breakout Box for Power Analyzers, Europe configuration | Request a quote | |
Datasheet | BB1000-NA | Breakout Box for Power Analyzers, North American configuration | Request a quote | |
Datasheet | BB1000-UK | Breakout Box for Power Analyzers, United Kingdom configuration | Request a quote | |
Datasheet | BB1000-UN | Breakout box with universal power receptacle | Request a quote | |
Datasheet | CL1200 | Current Clamp, 0.1A – 1200A | Request a quote | |
Datasheet | CL200 | Current Clamp, 0.5A – 200A | Request a quote | |
Datasheet | CT-100-M | Fixed-Core Current Transducer, Hall Effect, up to 100A | Request a quote | |
Datasheet | CT-1000-M | Fixed-Core Current Transducer, Hall Effect, up to 1000A | Request a quote | |
Datasheet | CT-1000-S | Fixed-Core Current Transducer, High Accuracy, up to 1000A (requires external power supply) | Request a quote | |
Datasheet | CT-200-M | Fixed-Core Current Transducer, Hall Effect, up to 200A | Request a quote | |
Datasheet | CT-200-S | Fixed-Core Current Transducer, High Accuracy, up to 200A | Request a quote | |
Datasheet | CT-60-S | Fixed-Core Current Transducer, High Accuracy, up to 60A | Request a quote | |
Datasheet | PA-LEADSET | STACKABLE BANANA TEST LEADS, SET OF 4, SAFETY SHROUDED WITH INSULATED ALLIGATOR CLIPS, 1000V CAT II, 30A | Request a quote | |
Datasheet | PA-EXT-LEADSET | STACKABLE 2mm TEST LEADS FOR EXTERNAL CURRENT SENSOR INPUT | Request a quote |
Reviews
There are no reviews yet.