Applications
Minerals, Mining, Geology, Cement
The S8 TIGER Series 2 is the ideal WDXRF instrument for geological monitoring covering almost the entire periodic table. With its unrivalled analytical flexibility it detects major elements and traces in one run. With the selection of high resolution analyzer crystals, such as the LiF 220 and the high intensity crystal XS-400, it enables geologists to get the entire information they need.
At the same time the S8 TIGER Series 2 provides outstanding performance and analytical precision for process control in base metal mining and for industrial minerals: With its HighSense detector technology with up to 2 Mio cps it delivers the precision process engineers need. Low cost of operation, instrument uptime (SampleCare) and ease of use with EZ Ergo (TouchControl, EasyLoad) optimal productivity is ensured.
The S8 TIGER comes with the specialized series of GEO-QUANT solutions for mining and geological applications:
- GEO-QUANT T for traces
- GEO-QUANT BASIC for major and minor elements
- GEO-QUANT ADVANCED for wide element ranges
- GEO-QUANT Iron Ore with ISO 9516 compliance
The S8 TIGER Series 2 is the perfect choice for the laboratories in cement plants: With HighSense WDXRF technology and the specialized analyzer crystal XS-CEM it delivers the precision for all process materials (raw materials, raw mix, clinker, hot meal, cement) and secondary materials (blast furnace slags, AFR’s). Special requirements, such as trace element detection in alternative fuels and green eco cement or sulfur speciation is done easily with the S8 TIGER Series 2.
CEMENT-QUANT is the perfect solution with the S8 TIGER Series 2. It delivers ASTM C-114 or ISO 29581 performance from the start for all cement types. GEO-QUANT BASIC works perfect for all raw materials and GEO-QUANT T rounds up the setup for heavy metal free eco cements.
Petrochemistry, Refinery, Polymers
There is no better instrument than the S8 TIGER Series 2 for all petrochemical WDXRF applications. Safe liquid sample handling with DirectLoading, SampleCare and automatic liquid sample detection high instrument uptime is guaranteed.
The low temperature tube head and atmospheric helium mode are enabling even the safe analysis of volatile samples, such as fuels and the detection limit of sulfur in gasoline with 0.2 ppm (100s @ 4kW with XS-GE-C) calls for world record! Two helium modes and the small sample chamber are the main reasons for the unique low cost of operation – the maximum mileage with one bottle of helium!
The leading WDXRF solution PETRO-QUANT enables accurate trace analysis of more than 30 elements in fuels, oils, used engine oils, fat and any other hydrocarbon matrix. If standard compliant analysis is required, no problem, our norm packages are simply added to PETRO-QUANT:
- ASTM: D 2622, D 6443, D 5059
- EN ISO: 14596, 14597, 15597, 20884
- DIN: 13723, 51363, 51391, 51399, 51431, 51790
And many more
The analysis of impurities in virgin polymers at sub-ppm level or additives in filled plastics up to several % – all this is mastered with the S8 TIGER Series 2. Catalysts with best precision and quick monitoring of toys for toxic elements is done with a simple touch on the TouchControl interface – the analytical performance of the S8 TIGER Series 2 is on spot for all these tasks. With the low-temperature-tube head long measurement times for traces at sub-ppm level or the high precision analysis with the XS series crystals the results of all polymers are quickly available.
POLYMER-QUANT A is the ready-to-analyze solution for the analysis of typical elements in polymers, such as Mg, Al or Zn. RoHS-QUANT ABS provides an exclusive set of calibration samples for WEEE/RoHS compliance testing. Complicated applications are made easy with the S8 TIGER Series 2.
Metals
Quality and process control of all relevant materials in metal production is a straight-forward job with the S8 TIGER Series 2. Based on HighSense technology it provides a maximum intensity to achieve best counting statistics for all important elements. TouchControl and EasyLoad enables operators an intuitive, failsafe operation. A plus on precision and instrument uptime comes with the DirectLoading of the S8 TIGER.
The S8 TIGER Series 2 provides the analytical flexibility one need for all materials ranging from metals, refractories, additives and slags. At the same time different sample types – solids, pressed pellets, fused beads and liquids (oils) are handled safely and quickly.
METAL-QUANT enables users to get the S8 TIGER Series immediately into operation without long calibration work covering wide material ranges. The dedicated SLAG-QUANT delivers quick control of all slag materials in the laboratory.
MLplus is the ideal software for the analysis of single and multiple layers on metals, no matter if anti-corrosion- systems or decorative finishing it enables the analysis of layer composition and thickness in the nm – mm range. Setup seems too complicated – no problem, the simulation mode of MLplus helps to define even difficult applications without any prior measurement.
Research & Development, Academia
The S8 TIGER Series 2 is the ideal WDXRF instrument to serve scientist in R&D and academia solving the most challenging tasks. With HighSense technology, its unrivalled analytical flexibility and the optimal conditions for light elements the S8 TIGER Series proves to deliver spot on results! The unique analyzer crystals are extending the application range of WDXRF:
- The XS-N HS provides two times more sensitivity compared to traditional optics
- The XS-C enables better detection limits by reducing the background by 30%
QUANT-EXPRESS fully integrated standard solution extends the analytical flexibility when adding elements to user calibrated applications. An easy way to master non-routine challenges!
XRF2 small spot mapping with 300 nm spot size and 100 nm step size enables small spot mapping with best light element sensitivity of WDXRF, optimal resolution better than EDXRF and better detection limits for heavy elements due to the HighSense optics. An indispensable tool for archaeology, batteries, electronics and new materials!
MLplus is the ideal software for the analysis of single and multiple layers on semiconductors and new materials. It enables the analysis of layer composition and thickness in the nm – mm range. The simulation mode of MLplus helps to define even new applications without any prior measurement. Based on the advanced light element performance with HighSense beam path and the XS Series crystals even complicated multilayer systems can be analyzed – more accurate and more precise!
Technical Details
Systems | S8 TIGER 1 kW 1kW 50 kV max. 50 mA max. | S8 TIGER 3 kW 3 kW 60 kV max. 150 mA max. | S8 TIGER 4 kW 4 kW 60 kV max. 170 mA max. | |
X-ray tubes | Rh, 75 μm Be Window | Rh, 75 μm Be Window Rh, 50 μm Be Window, SampleCare protective coating Rh, 28 μm Be Window, SampleCare protective coating Cr, max.3.3 kW | Rh, 75 μm Be Window Rh, 50 μm Be Window, SampleCare protective coating Rh, 28 μm Be Window, SampleCare protective coating Cr, max.3.3 kW | |
Collimator | Automatic collimator changer (up to 4) | |||
Analyzer crystals | Automatic crystal changer (up to 8) Included: XS-55, PET, LiF (200) Optional: XS-B, XS-C, XS-N, XS-PET-C, XS-CEM, XS-Ge-C, LiF (220), LiF (420), ADP, Ge, TlAP, InSb, XS-N-HS, XS-100, XS-400, XS-InSb-C | |||
DynaMatch™ | Linear intensity range more than 13 million cps | |||
HighSense Detectors | Proportional flow counter and Scintillation Counter: Capacity more than 3 Mio cps, 2 Mio cps linear range | |||
XRF2 | High Resolution and high Intensity Element Mapping with 0.3 mm and 1.25 mm spot (FWHM) | |||
Automated Mask Changer | Automatic masks : closed (SampleCare;) 34 mm, 28 mm, 23 mm, 18 mm, 8 mm (BeamGuide), 5 mm (BeamGuide) | |||
TouchControl™ 1) | Integrated touchscreen for easy and intuitive operation | |||
SampleCare™ 1) | X-ray tube and goniometer protected by contamination shields Sample and spectrometer chamber separated by programmable vacuum seal | |||
EasyLoad™ 1) | Automatic sample recognition Portable sample trays | |||
Power requirements | 208 – 240 V (1P/3P) 50/60 Hz | 208 V, 60 Hz (1P/3P) 230 V, 50/60 Hz (3P) | ||
Compressed air | Not required | |||
Detector gas | P5 gas (5% methane, 95% argon) for flow counter P10 gas (10% methane, 90% argon) for flow counter | |||
External cooling water | No cooling water | Cooling water Water consumption automatically regulated and minimized, short term interruptions are compensated | ||
Dimensions (height x width x depth) | 135 cm x 84 cm x 90 cm; 53.1” x 33.1” x 35.4” | 135 cm x 84 cm x 104 cm; 53.1” x 33.1” x 41” | ||
Touchscreen: Allows additional width of 49 cm (19.3’’) | ||||
446 kg | 476 kg | |||
Quality & safety | DIN EN ISO 9001:2008 CE certified Fully radiation protected system; radiation < 1 μSv/h (BfS 09/07 V RöV) |
1) optional packages
Reviews
There are no reviews yet.